Detailed Introduction to H05V-K/H07V-K Flexible Copper Cable (1.5mm², 2.5mm², 300/500V, PVC Insulated)

I. From the Perspective of the Product Itself

(1) Specification Parameters
The specification parameters of H05V-K/H07V-K Flexible Copper cables are carefully designed to fully meet the various performance requirements of low-voltage electrical systems, providing stable and reliable power transmission guarantees for electrical equipment in different scenarios.
In terms of conductor specifications, 1.5mm² and 2.5mm² are the core specifications of the two cables. The 1.5mm² conductor is composed of 50-60 strands of fine Copper Wires with a diameter precisely controlled at 0.15mm. This multi-strand stranded structure endows the conductor with excellent Flexibility, enabling it to easily adapt to various bending paths during installation. The 2.5mm² conductor is stranded with 80-90 strands of fine copper wires of the same diameter. Compared with the 1.5mm² conductor, it has more strands and can carry a larger current.
Conductivity is one of the key indicators to measure the quality of cables. At 20°C, the DC resistance of the 1.5mm² conductor is strictly controlled within the range of not more than 12.1Ω/km, and the DC resistance of the 2.5mm² conductor is not more than 7.41Ω/km. This excellent conductivity ensures that the loss of electrical energy during transmission is minimized, improving the efficiency of power transmission.
In terms of current-carrying capacity, the two cables show obvious differences according to their specifications. When the 1.5mm² cable is laid in the air, its current-carrying capacity is about 16-25A, which is sufficient to meet the power supply needs of lighting fixtures, small household appliances and other equipment in homes and small commercial places. The 2.5mm² cable has a current-carrying capacity of about 24-32A when laid in the air, which can provide stable power support for high-power appliances such as air conditioners and electric water heaters. It is worth noting that the current-carrying capacity will be affected by the laying method. When using underground laying, the current-carrying capacity will increase to a certain extent due to the change in heat dissipation conditions.
The parameters of the insulation layer vary by model. Both H05V-K and H07V-K cables use PVC materials for their insulation layers, but the thicknesses are different. In H05V-K cables, the insulation thickness of 1.5mm² is about 0.8mm, and that of 2.5mm² is about 0.9mm; the insulation layer of H07V-K cables is relatively thicker, with 1.5mm² being about 0.9mm and 2.5mm² being about 1.0mm. The thicker insulation layer provides stronger insulation protection for H07V-K cables, enabling them to operate safely in more complex environments. The dielectric strength of the insulation layers of both cables exceeds 20kV/mm, and the insulation resistance is not less than 100MΩ·km at 20°C, which means they can effectively block current, prevent leakage and short-circuit accidents, and provide a solid guarantee for electrical safety.
The overall outer diameter of the cable also varies depending on the specification and model. The outer diameter of H05V-K 1.5mm² cable is about 4.5-5.0mm, and that of 2.5mm² is about 5.5-6.0mm; the outer diameter of H07V-K 1.5mm² cable is about 5.0-5.5mm, and that of 2.5mm² is about 6.0-6.5mm. The smaller outer diameter makes the laying of cables in narrow spaces more convenient, saving installation space.
The minimum bending radius is an important parameter reflecting the flexibility of the cable. The minimum bending radius of both cables is 4-6 times the outer diameter of the cable. Specifically, the static bending radius of H05V-K 1.5mm² cable is not less than 18mm, and the dynamic bending radius is not less than 27mm; the static bending radius of 2.5mm² cable is not less than 22mm, and the dynamic bending radius is not less than 33mm. The bending radius of H07V-K cables is basically the same as that of H05V-K cables of the same specification. This feature allows the cable to easily cope with complex installation environments, such as corner turns and Internal Wiring of equipment.
In terms of temperature resistance, the long-term operating temperature range of H05V-K cables is -15°C to 70°C, within which all performance of the cable remains stable. H07V-K cables have a wider temperature resistance range, with a long-term operating temperature of -25°C to 80°C, which can adapt to colder or slightly higher temperature environments, such as power supply for outdoor equipment in northern winters or internal wiring in small industrial workshops. In addition, both cables can withstand a certain degree of temperature rise under short-term overload conditions. H05V-K can reach a short-term overload temperature of 90°C for no more than 5 seconds; H07V-K can reach a short-term overload temperature of 100°C, also for no more than 5 seconds, which can cope with sudden current overloads.
In terms of mechanical properties, both cables perform well. The tensile strength is not less than 12MPa, and the elongation at break is not less than 150%, which means that the cable can withstand a certain degree of tensile and bending forces during installation and use, and is not prone to breakage or damage, ensuring the service life and safety of the cable.
(2) Characteristic Uses
H05V-K/H07V-K Flexible Copper Cables, with their diverse specifications and excellent performance, have extensive and important characteristic uses in civil, commercial, industrial and other fields, providing reliable power solutions for various electrical scenarios.
In the civil field, home decoration is one of the main application scenarios of these two cables. 1.5mm² cables are often used in home lighting circuits, connecting from the distribution box to chandeliers, wall lamps, spotlights and other lighting fixtures in various rooms. Their stable conductivity and appropriate current-carrying capacity can ensure the normal operation of the lighting system. At the same time, it is also suitable for power supply of small household appliances, such as table lamps, TVs, electric fans, routers, etc. These devices have low power, and 1.5mm² cables are sufficient to meet their power needs. 2.5mm² cables are responsible for powering high-power appliances in the home, such as air conditioners, electric water heaters, microwave ovens, induction cookers, etc. These devices require a large current during operation. The high current-carrying capacity and good stability of 2.5mm² cables can ensure their safe operation, avoiding safety hazards caused by cable overload.
Commercial places also have a strong demand for cables, and these two cables can be seen in shopping malls, hotels, office buildings and other places. In shopping malls, 1.5mm² cables can be used for lighting circuits in stores, cash registers, power supply for small display cabinets, etc. Their flexible characteristics facilitate laying in concealed spaces such as ceilings and wall interlayers without affecting the overall beauty of the mall. The power supply lines of lighting, TVs, air conditioners and other equipment in hotel rooms also often use these two cables. H07V-K cables, with their wider temperature resistance range, are more suitable for use in areas with slightly higher temperatures such as hotel kitchens to supply power to kitchen equipment such as refrigerators and microwave ovens. Office equipment in office buildings, such as computers, printers, copiers, etc., usually use 1.5mm² cables for power supply, while the air conditioning system in the office will choose 2.5mm² cables to meet its power requirements.
In the industrial field, the control lines of small mechanical equipment and the connecting lines of instruments are important applications of H05V-K/H07V-K Flexible Copper Cables. In small processing workshops, the control lines of various lathes, milling machines, drilling machines and other equipment need flexible wiring. The flexible characteristics of these two cables enable them to easily adapt to the complex internal structure of the equipment and complete the transmission of signals and power. Instruments and meters, such as oscilloscopes, multimeters, thermometers and other precision equipment, have high requirements for connecting lines. 1.5mm² cables, with their stable conductivity and good insulation, have become the ideal choice for connecting lines of these equipment. H07V-K cables, with their wider temperature resistance range, have more advantages in industrial environments with slightly higher temperatures. For example, they can maintain stable performance when wiring near baking equipment in small food processing plants or when used in mechanical workshops with slight temperature changes.
In temporary power supply scenarios, these two cables also play an important role. At construction sites, temporary lighting is essential. 1.5mm² cables can be connected to temporary street lamps, mobile lighting fixtures, etc., to provide sufficient light for construction workers. At the same time, small electric tools at the construction site, such as electric drills and angle grinders, can also use 1.5mm² or 2.5mm² cables for power supply, and a reasonable choice can be made according to the power of the tools. In outdoor activities, such as open-air concerts and sports events, temporarily built stage lighting, audio equipment, broadcasting equipment, etc., all need temporary power supply. The flexibility and portability of H05V-K/H07V-K cables make them the first choice for temporary power supply lines, facilitating staff to quickly arrange and disassemble the lines.
These two cables can also be used in the agricultural field. In greenhouses, the power supply lines of lighting systems, small ventilation equipment, irrigation pumps, etc., can use 1.5mm² or 2.5mm² cables, and the appropriate specification can be selected according to the power of the equipment. The low-temperature resistance of H07V-K cables makes them more advantageous in agricultural greenhouses in cold areas. Even in low-temperature environments in winter, they can ensure the normal operation of the cables, ensuring the normal operation of equipment in the greenhouses and providing a suitable environment for the growth of crops.
Some small equipment in the transportation field also use these two cables. For example, the internal wiring of lighting, audio, air conditioning and other equipment in small trucks and passenger cars can use 1.5mm² cables; while the power supply lines of refrigeration equipment in some small refrigerated trucks, due to the low working environment temperature, H07V-K cables will be a better choice, and their low-temperature resistance can ensure the normal operation of the cables in the low-temperature environment of refrigerated trucks.
(3) Material and Style
  1. Material

The material selection of H05V-K/H07V-K flexible Copper Cables is the basis for their excellent performance. The materials of the conductor and insulation layer are strictly screened and tested to ensure the quality and reliability of the cables.
The conductor is made of high-purity electrolytic copper with a purity of over 99.95%. High-purity copper has excellent conductivity, which is the key to ensuring efficient transmission of electrical energy by the cable. It can reduce the loss of current during transmission and improve the efficiency of power utilization. At the same time, copper has good ductility and plasticity, allowing fine copper wires to be smoothly drawn and stranded to form a Flexible Conductor. During processing, the copper wires undergo annealing treatment to further eliminate internal stress, improve the flexibility and fatigue resistance of the copper wires, so that the conductor is not easy to break under frequent bending and stretching, and prolong the service life of the cable. In addition, copper has a certain degree of corrosion resistance, and is not easy to oxidize and rust in normal use environments, which can maintain stable conductivity for a long time.
The insulation layer is made of polyvinyl chloride (PVC) material, which is a commonly used Insulation Material with many excellent properties. PVC material has good insulation performance, which can effectively block current, prevent leakage accidents, and ensure electrical safety. It also has good oil resistance and wear resistance. In daily use, it can resist the erosion of oil stains and damage caused by mechanical friction, protecting the internal conductor from damage. PVC material has good chemical stability, is not easy to react with common chemical substances, and can maintain stable performance in various environments. At the same time, PVC material is self-extinguishing. When exposed to an open flame, it can extinguish itself and will not burn continuously. This characteristic greatly reduces the risk of fire and improves the safety of the cable. In addition, PVC material is easy to process and form, and can be evenly extruded and wrapped around the conductor through an extrusion process to form an insulation layer with uniform thickness and smooth surface, ensuring the quality stability of the cable.
  1. Style

H05V-K/H07V-K flexible copper cables are of single-core style, which has many advantages. The single-core structure makes the cable more flexible, enabling it to more easily pass through narrow pipes, trunking and small spaces inside equipment, adapting to various complex installation paths. Compared with Multi-Core cables, when a single-Core Cable fails, troubleshooting and maintenance are more convenient, and the problem can be quickly located, saving maintenance time and cost.
The cable has a circular appearance with a smooth and flat surface. The circular design allows the cable to be stressed more evenly when bent, reducing the phenomenon of local stress concentration, which is beneficial to prolonging the service life of the cable. The smooth surface is not only beautiful, but also can reduce friction with other objects during laying, reducing the possibility of cable damage.
In terms of color, the two cables provide a variety of options, commonly including black, gray, white, etc. Different colors are convenient for distinguishing different circuits during wiring, such as lighting circuits and power circuits, improving the efficiency and accuracy of installation. At the same time, the choice of color can better match the use environment. For example, in home decoration, white cables can better blend with the wall color without affecting the overall beauty.
The surface of the cable clearly prints relevant identification information, including model (H05V-K or H07V-K), specification (1.5mm² or 2.5mm²), rated voltage (300/500V), manufacturer, production date, certification mark, etc. This information not only facilitates users' identification and selection, but also provides a basis for cable quality traceability, ensuring that users use qualified products.
In terms of length, the two cables can be customized according to users' needs. Common standard lengths include 100 meters, 200 meters, 500 meters, etc. For special length requirements, manufacturers can also carry out corresponding production and cutting to meet the installation needs of different users.
(4) Production Process
The production process of H05V-K/H07V-K flexible copper cables is complex and rigorous. From the processing of raw materials to the inspection of finished products, each link has strict quality control to ensure that the performance of the cables meets the design standards.
The production of the conductor is the first step in cable manufacturing, starting with the drawing of copper rods. High-purity electrolytic copper rods are selected and drawn through a wire drawing machine for multiple passes to draw the copper rods into fine copper wires with a diameter of 0.15mm. During the drawing process, it is necessary to accurately control the drawing speed, tension and die size to ensure that the diameter of the copper wire is uniform and the surface is smooth without defects. The drawn copper wire needs to be annealed. The copper wire is heated to 300-500°C, kept for a certain period of time and then slowly cooled. Annealing treatment can eliminate the internal stress generated during the drawing process of the copper wire, improve the flexibility and ductility of the copper wire, and prepare for the subsequent stranding process.
Copper wire stranding is a key process for forming conductors. According to different cable specifications, a corresponding number of fine copper wires are stranded by a stranding machine. For 1.5mm² conductors, 50-60 strands of fine copper wires are stranded according to a certain stranding pitch; for 2.5mm² conductors, 80-90 strands of fine copper wires are stranded. The stranding pitch is usually controlled at 10-15 times the outer diameter of the conductor. The selection of this parameter not only ensures the flexibility of the conductor, but also ensures the structural stability and conductivity of the conductor. During the stranding process, the tension of the copper wire should be kept uniform to avoid loose strands, broken strands and other phenomena, so as to ensure the quality of the conductor. After stranding, the conductor is inspected for appearance and size to ensure that its roundness and cross-sectional area meet the design requirements.
The extrusion molding of the insulation layer is one of the core links in cable production. PVC Insulation Material particles are added into the hopper of the extruder and heated to melt the material. The temperature control of the extruder is crucial. For the PVC materials used in H05V-K and H07V-K cables, the extrusion temperature is usually controlled between 160-190°C. Different types of PVC materials may need to fine-tune the temperature parameters to ensure that the material is fully melted without decomposition. The molten PVC material is evenly extruded and wrapped around the Copper Conductor through an extrusion die to form an insulation layer. During the extrusion process, it is necessary to accurately control the extrusion speed and die pressure. The extrusion speed must match the traction speed of the conductor to ensure uniform thickness of the insulation layer; the stability of the die pressure can ensure that the insulation layer is tightly combined with the conductor, avoiding defects such as bubbles, eccentricity and pinholes. The extruded cable immediately enters a cooling water tank for cooling to quickly solidify and shape the insulation layer. The cooling water temperature is generally controlled at 20-30°C, and the cooling time depends on the cable specification and insulation layer thickness.
The cooled cable needs to be printed. The model, specification, rated voltage, manufacturer, production date, certification
mark, and other information are clearly printed on the surface of the cable through a printing machine. Wear-resistant special ink is used for printing to ensure that the information remains clearly visible during the service life of the cable. During the printing process, it is necessary to ensure that the handwriting is clear, complete, and accurately positioned without affecting the appearance and performance of the cable.
Finished product inspection is the final step to ensure cable quality, involving multiple items such as appearance inspection, dimension measurement, electrical performance testing, and mechanical performance testing. Appearance inspection mainly checks whether the cable surface has scratches, bubbles, depressions, impurities, and other defects, and whether the insulation layer is uniform and smooth. Dimension measurement includes parameters such as conductor diameter, insulation layer thickness, and cable outer diameter to ensure they meet design requirements. Electrical performance testing includes insulation resistance testing, dielectric strength testing, and DC resistance testing. The insulation resistance test is conducted at 20°C, requiring not less than 100MΩ·km; the dielectric strength test checks the voltage resistance capability of the insulation layer by applying a certain voltage, requiring a dielectric strength exceeding 20kV/mm; the DC resistance test verifies whether the conductivity of the conductor meets the standard. Mechanical performance testing includes tensile strength testing and elongation at break testing, ensuring that the tensile strength of the cable is not less than 12MPa and the elongation at break is not less than 150%. In addition, the cable will also undergo temperature resistance testing, aging resistance testing, etc., to verify its performance stability under different environmental conditions. Only cables that pass all inspection items are deemed qualified products and enter the finished product warehouse waiting for delivery.

II. From the Perspective of General Product Information

(1) Packaging
The packaging design of H05V-K/H07V-K flexible copper cables fully considers protecting the cables during transportation, storage, and handling, while taking into account convenience and clear identification, ensuring that the cables can reach users in good condition.
For long-length cables (usually 100 meters and above), cable reels are used for packaging. There are two types of cable reels: wooden and plastic. The appropriate cable reel is selected according to the specification and weight of the cable. 1.5mm² and 2.5mm² cables are relatively light in weight, so wooden cable reels are generally used. Wooden cable reels are low in cost and have a certain degree of strength and toughness, which can protect the cables from damage. The diameter of the cable reel is usually 500-800mm, and the width of the reel is 150-300mm. The specific size depends on the length and specification of the cable. When packaging, the cable is neatly wound on the cable reel, and a certain tension is maintained during winding to prevent the cable from loosening or tangling. After winding, the surface of the cable is wrapped with a layer of plastic film, which has good moisture-proof and dust-proof effects, preventing the cable from being polluted by moisture, dust, and other impurities during storage and transportation.
For short-length cables (usually less than 100 meters), they are packaged in coils. The cable is wound into a coil with a diameter of 200-300mm, and fixed with plastic straps at intervals of 30-50mm to ensure that the coil does not loosen. Then, the coil is put into a thick cardboard box, and the gap in the box is filled with soft materials such as foam or bubble film to buffer and protect the cable, avoiding collision and damage during transportation.
No matter what kind of packaging is used, clear labels are attached to the packaging. The labels include the product name, model, specification, length, rated voltage, production date, batch number, manufacturer's name, contact information, and other detailed information, which is convenient for users to check and confirm when receiving the goods. At the same time, the labels also indicate warning information such as "moisture-proof", "light handling", and "no heavy pressure" to remind transportation and handling personnel to operate correctly.
(2) Transportation
The transportation of H05V-K/H07V-K flexible copper cables needs to comply with relevant regulations and operating procedures to ensure the safety and integrity of the cables during transportation.
Before transportation, the cable packaging must be carefully inspected. For cable reels, check whether the structure is intact, whether the cable is firmly fixed, and whether the plastic film is intact; for coil-packed cables, check whether the cardboard box is damaged, whether the plastic straps are tight, and whether the filling materials are sufficient. If any problems are found, they must be repaired or repackaged in time.
According to the quantity, length, and transportation distance of the cables, appropriate transportation tools are selected. For short-distance transportation with small quantities, ordinary vans or trucks can be used; for long-distance transportation with large quantities, logistics vehicles with closed compartments are preferred to avoid the cables being exposed to rain, snow, and sunlight.
When loading, attention should be paid to light handling to avoid violent collision and extrusion. For cable reels, they should be placed stably, and the reels should be fixed with ropes or brackets to prevent them from rolling during transportation. For coil-packed cables, they should be stacked neatly, and the stacking height should not be too high to prevent the bottom box from being crushed. At the same time, the cables should be separated from sharp objects, chemicals, and other items that may damage the cables.
During transportation, the driver should drive steadily, avoid sudden braking, sharp turns, and severe bumps, and strictly abide by traffic rules. For long-distance transportation, stop regularly to check the condition of the cables, such as whether the packaging is damaged, whether the cable reels are loose, etc. If any abnormalities are found, take timely measures to deal with them.
In special weather conditions, corresponding protective measures should be taken. In rainy and snowy weather, ensure that the transportation vehicle is rainproof and snowproof to prevent the cables from getting wet; in high-temperature weather, avoid the cables being exposed to direct sunlight for a long time to prevent the insulation layer from aging due to high temperature.
After arriving at the destination, the unloading operation should be carried out in accordance with the correct method. Use appropriate tools such as forklifts or manually unload, and continue to pay attention to light handling to avoid damaging the cables. After unloading, place the cables in a dry, ventilated, and flat place, away from fire sources, heat sources, and corrosive substances.
(3) Delivery
The delivery process of H05V-K/H07V-K flexible copper cables is standardized and efficient, ensuring that the cables can be delivered to users on time and in good condition.
After receiving the user's order, the sales staff will confirm the product details with the user again, including the model, specification, quantity, delivery address, and delivery time, to avoid errors. Then, the order information is sent to the warehouse, and the warehouse staff will retrieve the corresponding cables from the warehouse according to the order requirements.
The warehouse staff will conduct a detailed inspection of the retrieved cables, including checking whether the model, specification, and quantity are consistent with the order, and whether the packaging is intact. After the inspection is passed, the delivery note, product certificate, and inspection report are attached to the packaging, and the goods are handed over to the designated logistics company.
The logistics company will generate a logistics waybill according to the delivery information, and the sales staff will promptly feedback the waybill number and logistics 查询方式 to the user, so that the user can track the transportation status of the goods in real time. For urgent orders, the company can arrange for expedited transportation, such as express delivery, to ensure that the goods arrive at the destination as soon as possible.
During the transportation process, the sales staff will keep in touch with the logistics company and the user. If there is any delay in transportation or damage to the goods, they will actively coordinate and deal with it to ensure that the user's rights and interests are protected. After the user receives the goods and confirms that they are correct, the delivery process is completed.
(4) Samples
To help users better understand the performance and quality of H05V-K/H07V-K flexible copper cables, the company provides sample services, allowing users to test and evaluate before purchasing in large quantities.
Users can apply for samples through the company's official website, phone calls, emails, and other channels. When applying, users need to provide basic information such as the required product model, specification, quantity, their own unit name, contact person, and contact information. The company's customer service staff will reply to the user within 2 working days to confirm the sample information and inform the user of the relevant matters such as sample fees and freight.
In general, the company provides 1-5 meters of samples for free, but the user needs to bear the freight. For special specifications or large quantities of samples, the company will charge a certain sample fee, which can be deducted from the payment of the subsequent bulk order. The samples are produced in accordance with the same standards and processes as the bulk products, ensuring that the samples have the same performance and quality as the bulk products.
The samples are packaged in small coils, and the surface of the sample is printed with the model, specification, and other information. At the same time, the sample is accompanied by a sample test report, which includes the test results of the sample's electrical performance, mechanical performance, and other indicators, providing users with detailed reference data. The samples are usually delivered by express, and the user can receive them within 3-5 working days after the application is approved.
After receiving the sample, if the user has any questions about the sample's performance, installation, or use, they can contact the company's technical staff, who will provide professional answers and guidance.
(5) After-sales Service
The company attaches great importance to the after-sales service of H05V-K/H07V-K flexible copper cables and provides comprehensive after-sales support to solve users' problems and ensure user satisfaction.
The product quality warranty period is 12 months from the date of delivery. During the warranty period, if the cable has quality problems such as insulation breakdown, conductor oxidation, or sheath cracking due to manufacturing defects, the company will provide free repair, replacement, or return services after confirming the problem. Users need to provide relevant materials such as purchase invoices and product certificates when applying for after-sales service.
The company has a professional after-sales service team composed of experienced technical personnel. Users can contact the after-sales service team through the after-sales hotline, email, or online customer service. The after-sales staff will respond to the user's request within 24 hours, understand the specific situation of the problem in detail, and provide solutions. For problems that cannot be solved by phone or online communication, the company will arrange technical personnel to go to the site for handling within 48 hours (depending on the distance).
In addition to quality problem handling, the after-sales service team also provides technical guidance services. They can provide users with professional advice on cable installation, laying, maintenance, and other aspects, help users correctly use and maintain the cables, and extend the service life of the cables. The company can also provide users with relevant technical documents, such as product manuals and installation guides, according to user needs.
The company establishes a user feedback mechanism to collect users' opinions and suggestions on products and services. For the problems reflected by users, the company will conduct in-depth analysis and continuous improvement to improve product quality and service level. Regular user return visits are also carried out to understand the use of the cables and provide necessary technical support and services.
Tìm hiểu thêm về các sản phẩm cáp
Liên hệ với Công ty TNHH Công nghệ Cáp Hongtai
Liên hệ với chúng tôi

Công ty TNHH Công nghệ Cáp Hongtai

E-mail: export@qlcables.com

           sales@qlcables.com

Tel/WhatsApp:+86-18032066271

Thêm khu vực phát triển công nghiệp Xiaokou, Hạt Ningjin, Thành phố Xingtai , tỉnh Hà Bắc, Trung Quốc

Bản quyền © Công ty TNHH Công nghệ Cáp Hongtai  Hỗ trợ kỹ thuật:Công nghệ Ronglida


Sơ đồ trang web

Trang web này sử dụng cookie để đảm bảo bạn có được trải nghiệm tốt nhất trên trang web của chúng tôi.

Chấp nhận từ chối